- C1 |
- C2 |
- C3 |
- C4 |
- C5 |
- C190 |
- C101 |
- standard features |
- cost options
COST OPTIONS
COST OPTIONS
OF CYLINDRICAL PORTALS
TYPE OF GLASS
Glasses
You can choose the best type of glass that
meets your needs.
Vandal proof glass:
– Glass type P2A EN356 and thickness 11mm.
– Glass type P4A EN356 and thickness 14mm.
– Glass type P6B EN356 and thickness 27mm.
– Glass type P7B EN356 and thickness 21mm.
Bullet proof glass:
– Glass type BR3 EN 1063 and thickness 27mm.
– Glass type BR4 EN 1063 and thickness 31mm.
SPECIAL VERSIONS
K VERSION
R VERSION
You can easily lay the Alluser security portal on the floor and fix it with screws.
AVAILABLE INTERNAL PORTAL HEIGHTS
ATTACK RESISTANT CLASS RC3
Class RC3 resistance has been tested and certified by an accredited EU Test Laboratory against mechanical manual tools among which long screwdriver, set of wood and plastic wedges, crowbar, pliers, hammer, knife, tweezers, jack, set of steel wire hooks.
Intended severity risk/attack:
Deliberate forced entry of a well-protected domestic residence or commercial property using a wide choice of tools with little regard for noise.
ATTACK RESISTANT CLASS RC4
Class RC4 resistance has been tested and certified by an accredited Test Laboratory against attack of an experienced thieves, security as in Class RC3 + resistance against tools among which hacksaw with HSS blades, axe, heavy hammer, plate shears, bolt cutter, electric drill.
Intended severity risk/attack:
experienced attempts at forced entry of commercial premises with no regards for noise.
OUTER FINISHINGS
BRUSHED STAINLESS STEEL
ALUMINUM
– Top canopy cladding + external central vertical frame cladding (Structure in RAL 9005 smooth)
– Internal/External Portal structure cladding (sliding doors frame, cover top, floorguide excluded)
For a full secure portal cladding you can also add clear anodized Aluminium Sliding door frames. This option is not available with Metal Detector.
POLISHED STAINLESS STEEL
RAL PEARL COLOURS
You can customize your portal by choosing between a broad range of RAL code colours.
However we also offer the possibility to choose one of the following pearl RAL colours!
RAL COLOURS
STANDARD FEATURES
1000, 1001, 1002, 1003, 1004, 1005, 1006, 1007, 1001, 1012, 1013, 1014, 1015, 1016, 1017, 1018, 1019, 1020, 1021, 1023, 1024, 1027, 1028, 1032, 1033, 1034, 2000, 2001, 2002, 2003, 2004, 2008, 2009, 2010, 2011, 2012, 3000, 3001, 3002, 3003, 3004, 3005, 3007, 3009, 3011, 3012, 3013, 3014, 3015, 3016, 3017, 3018, 3020, 3022, 3027, 3031, 4001, 4002, 4003, 4004, 4005, 4006, 4007, 4008, 4009, 5000, 5001, 5002, 5003, 5004, 5005, 5007, 5008, 5009, 5010, 5011, 5012, 5013, 5014, 5015, 5017, 5018, 5019, 5020, 5021, 5022, 5023, 5024, 6000, 6001, 6002, 6003, 6004, 6005, 6006, 6007, 6008, 6009, 6010, 6011, 6012, 6013, 6014, 6015, 6016, 6017, 6018, 6019, 6020, 6021, 6022, 6024, 6025, 6026, 6027, 6028, 6029, 6032, 6033, 6034, 7000, 7001, 7002, 7003, 7004, 7005, 7006, 7008, 7009, 7010, 7011, 7012, 7013, 7015, 7016, 7021, 7022, 7023, 7024, 7026, 7030, 7031, 7032, 7033, 7034, 7035, 7036, 7037, 7038, 7039, 7040, 7042, 7043, 7044, 8000, 8001, 8002, 8003, 8004, 8007, 8008, 8011, 8012, 8014, 8015, 8016, 8017, 9019, 8022, 8023, 8024,8025, 8028, 9001, 9002, 9003, 9004, 9005, 9006, 9007, 9010, 9011, 9016, 9017, 9018
RAL PEARL COLOURS
COST OPTIONS
1035, 1036, 2013, 3032, 3033, 4011, 4012, 5025, 5026, 6035, 6036, 7048, 8029, 9022, 9023
RAL PEARL COLOURS
You can customize your portal by choosing between a broad range of RAL code colours (see the list of available RAL colours – standard features).
However we also offer the possibility to choose one of the following pearl RAL colours!
preventing tailgating and piggybacking
A.P.D
TWO-ZONE PRESSURE MAT
How it works.
A Voice message invites the user to step onto the two-zone pressure mat grey central area, which verifies the correct position by using pressure sensors. Then Alluser APD starts the volumetric analysis. In case both conditions are satisfied, the user can exit the Alluser security portal. In case more than one person is detected or a user is standing on the black peripheral pressure mat zone, access is denied. It is recommended in combination with APD to increase the security level. Alluser security anti-tailgating systems support your access control system for use at unattended building entrances, office entrances and for entrances into high security internal areas, (i.e. data centers, offices with time & attendance, nuclear power stations, 24/7 gyms, R&D Labs, Government premises etc.)
ONE-ZONE PRESSURE MAT
SECURITY PORTAL CONTROLLERS
METAL DETECTION
In the last 40 Years Alluser Security Portals’ Metal Detection has proved effective in reducing violent crime actions by preventing armed people to enter in public / private building. The system denies access to portal user carrying one or more objects belonging to a large range of threat objects – composed of magnetic, non-magnetic and mixed alloy metal weapons – thus eliminating one of the most serious threat to security (common installations: banks, jeweler shops, data centers, private companies, prisons, Courthouse etc.).
ADDITIONAL CONTROL PANEL
To satisfy your needs of controlling the same Alluser Security Portal from a second control desk.
The Additional Control panel has the same full functionality of your Main Control Panel, with the exception that the Main Control Panel has the priority on potential simultaneous commands.
WEB LAN CONTROL
The Web Lan Control permits simple and intuitive control of the Secure Portal through the web/intranet.
This cost option transforms the Portal into an IP address, therefore you can access to the portal through the LAN by using any computer and a browser. All portals have a different IP address.
Attention: Security of your entrance would depend upon your Intranet/Internet security level.
SERVICE MODE KEY
This option is a local ON/OFF keyswitch selector and cleaning mode function. Usually installed on the secure side on Portal frame, it has 3 functions:
1. it switches ON the Portal
2. it switches OFF the Portal
3. it enables the “Cleaning Mode” to allow an easy cleaning of the portal.
ELECTRONICS PART
EXTRA EMERGENCY LEVER
Each Alluser Security Portal is provided of one Mechanical Emergency Unlocking device.
Additional emergency levers can be added upon request to satisfy your special needs.
These levers can be provided of a key lock so to grant the security.
INTERIOR INTERCOM
Add an internal to the portal intercom (PTT), to communicate with the user inside the security portal from your remote control desk.
The interior intercom is connected with the Control Panel (standard feature) and allows the communication in between the interior of the Portal and the Control panel. It works up to 50 mt in between security portal and control panel.
EXTRA SAFETY SENSOR
Any customization requires a proper safety.
Each Alluser Security Portal is provided with double safety control in the sliding doors movement, to prevent from injuries. In case you need to use our portal for a customized application which would require non-standard safety (i.e. people with visual impairment, bikes) you can simply share with us your requirements, and we can add extra safety sensors.
NIGHT LOCK
To increase the security when the Portal is in night mode, it’s possible to add an extra mechanical locking procedure.
How it works
The security manager switches the security portal in night mode from the control panel or service mode, and last exit the secure area (either using the secure portal with first and last transit procedure, or an alternative exit). At the non secure side of the security portal he locks the non secure side mechanically and denies any automatic door opening command by simply turning the night lock key.
Choose it together with first transit and last exit option in applications where you don’t want to allow transit over a certain period of time (i.e. jewellery shop outside business hours overnight, offices outside working hours, etc.)
RAIN TOP COVER
Alluser security portals are not designed to be exposed to weather agents.
For Outdoor installations it is always mandatory a protective building canopy above the portal.
Only then Rain Cap Top Cover is a suggested option.
Included with this option, non secure side traffic light is supplied with a water resistant treatment.
SAFETY DEVICE
LOCKED TOP COVER
Reinforced top canopy cover when exposed on the non secure side and light weight secure side top canopy cover accessible with key locks only.
RESCUE PUSH BUTTON
Alluser rescue push button is a vandal resistant brushed steel push button inside your security Portal.
In case a user feels he is waiting too long inside the portal with both doors locked, then user can push it to open the portal door which last closed, and safely exit the portal.
Please note that this Rescue procedure is managed by an electronic board and it is not a mechanical unlocking device.
INTERNAL ALCOVE AND EXTERNAL SUPPORT BRACKETS
Don’t stress you out thinking where to fix your A.C. device inside/outside the Alluser security portal.
Each Alluser security portal is compatible with third parties A.C. (access control) device (i.e badge readers, proximity readers, biometric readers, etc.), whether verification is required outside the portal or inside the portal when a user is inside with both doors closed:
– External support brackets provides the proper place for your access control device without occupying security portal entrance.
– Internal Alcove accommodates the installation of your optional internal access control device, safely preventing finger trap inside the security portal.
CONNECTION BOARD
Connection Board provides a wide range of IN/OUT dry contact signals, which allows an easy interface in-between the Security Portals and your Building Features (i.e. access control managing system, fire alarm, tamper alarms, whether user properly accessed to your secure area or the user got rejected because of a security violation, etc.).
For every signal an LED indicator light provides an immediate visual feedback of the status of the function, to help for an easier integration.
FIRST & LAST TRANSIT
You no longer need another door to enter/exit the secure area outside working hours
How Last Exit works:
The security manager switches the security portal in night mode from the control panel or service mode, then he pushes the secure side traffic light to start the procedure and uses its own authorization Key (Mechanical Key, Proximity Key, Electronic Key). Alluser security portal allows only one transit in the way out so that the security manager can leave the secure area. After completing the transit, the security portal goes back to night mode (both doors locked and portal empty). How First Entry works: The security manager pushes the non secure side traffic light to start the procedure and then uses its own authorization Key (Mechanical Key, Proximity Key, Electronic Key). Alluser security portal allows only one transit in the way in so that the security manager can enter the secure area. After completing the transit, the security portal goes back to night mode (both doors locked and portal empty). Once inside security manager turn on (stand by mode) the security portal to allow the automatic transit as defined in access protocol.